Air pressure controller for rooms
Compact
Galvanized steel
Factory calibrated
Noise reduction
The AV unit housing of the OPTIMA-R-PC...BM as well as the control damper blade is made from galvanized sheet steel making it tough and durable.
The controllers are factory calibrated as standard to the air volume indicated in the table or upon request can be adjusted to site-required settings prior to dispatch.
OPTIMA-R-LPC...BM is a variable low pressure controller with or without an insulation. It is commonly used to control the air pressure in a room and is available in different sizes. OPTIMA-R-LPC...BM is commonly installed in offices, public spaces, laboratories, industrial plants and health care premises.
VAV unit housing is made from galvanised sheet steel. The controllers are factory calibrated as standard to the default air pressure or upon request can be adjusted to site-required settings prior to dispatch on Pmin and Pmax range. This must be indicated prior to ordering the units to ensure adequate calibration in the factory. Gateway communication units can be provided and can be connected later in time to building management systems
Nominal data | |||
---|---|---|---|
Communication data | 1xAI, 1xAO, 2x(NO/NC, pot. free) | ||
Duct connection type | Circular | ||
Voltage (nominal) | 24 | V | |
Power consumption in wire | 2 | VA | |
Dimensions and weights | |||
Weight | 1.7 | kg |
Round variable pressure regulator for regulating the air pressure in areas covered by a ventilation system.It can be used for supply and exhaust air and is available in 15 sizes (DN 080–630 mm).The control components are assembled and wired at the factory.The connection pieces have lip seals on both sides and are suitable for air ducts according to EN 1506 or EN 13180.The damper position can be read from the axis.Leakage air rate with closed damper according to EN 1751, Class 4.Housing leakage air rate according to EN 1751, Class C.Actuators 24 VPressure control range up to +/- 75 PaFor measuring/controlling the supply or exhaust air pressure difference between room and atmosphereHigh measurement/control accuracy of 5%Static sensor for taking measurements, even in dusty atmospheresInsulated version to reduce radiated noiseEach controller is calibrated and adjusted at the factory.Controller with analog, BACnet, and MODBUS communication as standardMaterials and surfacesHousing and damper are made of galvanized sheet steelSeals on pipe connections and butterfly discPlain bearings made of plasticsOptionally with insulation under lagging section made of galvanized sheet steel.Insulation made of NBR/PVC (according to EN 13501-1) building material group B-s3, d0Technical specificationNominal sizes: 080–630 mmAttachmentsS – standard driveQ – Actuator with short transition time (high-speed actuator)QE – Actuator with short transition time (high-speed actuator) and electrical safety functionF – Actuator with mechanical safety function (spring return)Required separate accessories:– Pilot tube, maximum length 10 m– Pilot-tube-duct connector– Hose clamp for securing (optional) - Size: 80- Insulation: Without insulation- Equipment, Communication type: S: Standard actuator with transition time 120 s- Electrical Connections: AC/DC 24 V, modulating (VAV)- Airflow direction: Supply