Explosion proof axial wall fan
ATEX certified
Available with AC motors for 50 Hz
Installation in any position
The AW-EX fans are designed for use in challenging low pressure environments where explosive atmospheres can occur. They can be installed in any position and in a variety of harsh and hazardous environment.
The fans are ATEX-certified. The variants AW-EX 355 / 420 have explosion proof marking: II 2G Ex e IIB T4 and sizes AW-EX 550 / 650 have explosion proof marking: II 2G Ex e IIB T3.
The square wall plate is made of galvanized steel with powder coating in RAL9005.
The complete range is provided with inlet protection grid.
It is recommended to connect the electrical cable from the motor to any device via an ATEX-certified connection box.
The AW-EX fans use axial impellers. These are made of galvanized steel, are dynamically balanced and are paired with corresponding external rotor motors.
AW-EX fans are equipped with AC motors. The motors are suitable for 50Hz.
The AW-Ex fan motor is approved according to ATEX. Useful for Zone 1 and 2, groups IIA, IIB and temperature class T1, T2, or T3 (AW 355 and AW 420 also T4), ignition protection "e".
The Motor has a prewired integral PTC thermistor with external leads to be connected to a motor protection device as U-EK230.
The AC motors can be controlled by a 5-step regulator.
The AW fans can be installed in any position on wall or ceiling in indoor environments.
400V 3~ 50Hz | |||
---|---|---|---|
Nominal data | |||
Voltage (nominal) | 400 | V | |
Frequency | 50 | Hz | |
Phases | 3~ | ||
Input power | 130 | W | |
Input power kW | 0.13 | kW | |
Input current | 0.3 | A | |
Impeller speed | 1,435 | rpm | |
Air flow | max 720 | L/s | |
Air flow at max. efficiency | 665 | L/s | |
Temperature of transported air | max 40 | °C | |
Max temperature of transported air, when speed controlled | 40 | °C | |
Protection/Classification | |||
Enclosure class, motor | IP44 | ||
Insulation class | F | ||
Explosion proof marking | II 2G c Ex e IIB T4 | ||
Certificate | ZELM 05ATEX0279X | ||
Data according to ErP | |||
ErP ready | Not ErP relevant | ||
Ambient and duct temperature | |||
Ambient and duct temperature | -20 to 40 | °C | |
Dimensions and weights | |||
Weight | 9 | kg | |
Others | |||
Motor type | AC |
The box is made out of electroplated steel plate, powder- coated. Including protection guard. The installation is possible in each fitting position. The fan has an axial impeller with airfoils made out of electroplated, powder- coated steel plate. The actuation is carried out by an explosion- proofed, speed- controllable external rotor motor with completed barretter. A D/Y- capability of connection allows an double- rotation operation of the motor. For annealing the motor is situated inside the air flow. Impeller according to VDI 2060, quality class Q 6,3 and dynamically weigh heavy in two levels. Tested according to ATEX- Guideline 94-9-EG,conform to ATEX Directive 2014/34/EU. For the extraction of potentially explosive atmosphere of zone 1, category 2G and zone 2, category 3G. The fans are in zone 1, 2 and for the temperature levels T1, T2 and T3 applicable. The explosion group is "e" elevated safety Eexe II, T3. Appurtenances for the Ex- fan is available on enquiry.%MCEPASTEBIN%