AXC(F) - G Axial Fans

High pressure smoke extraction axial fan for garages and industrial applications

  • High pressure

  • Certified for 400°C/120min

  • Installation inside or outside of the fire zone

  • Two fans mounted in series

  • Configurable in the Axial Fans Configurator 

High pressure

Two unidirectionally rotating fans are mounted in series to provide very high pressure in systems with complicated ducting.

EN 12101-3 certified

The AXC(F)-G axial fans have been performance tested in accordance with multiple standards on the Systemair or AMCA fan test rig and are certified for 400°C/120min smoke extraction.

The complete range is certified for installing inside or outside of the fire zone.

Application

The AXC(F)-G is an axial fan ideal for use in garages and other industrial applications and provides effective extraction in operating temperatures up to  55°C continuously and up to 400°C for 2 hours.

Performance

The fan can be configured to suit the individual operating point. Therefore, the pitch angle is adjusted in the factory. This provides a wide range of performance and high flexibility in the selection.

Sturdy and dependable design

Corrosion-proof aluminum impellers, IE3 high-efficiency motors and a hot-dip galvanized steel casing ensure high quality and a long life time.

Flexibility

On request AXC fans can be customized with the following options:

  • Wide range of accessories

  • Various coating colors

  • Special motor versions e.g. up to 100°C, with corrosion protection C5 or for other voltages

  • FAT and final inspection reports are available

  • Noise reduction AXC-Box can be used

  • Shorter casing

  • Different positions for the terminal boxes

  • X-ray tested blades and hubs

Tested according to ISO 5801 and AMCA 210

The AXC axial fans have been performance tested in accordance with ISO 5801 and AMCA 210 standards on the Systemair or AMCA fan test rig. To select AMCA certified fans check the axial fan configurator.

Construction

The fan AXC(F)-G contains two unidirectionally rotating fans that are mounted in series . The casing is made from hot-dip galvanised steel according to ISO 1461 with pre-drilled flanges. The terminal box with IP 65 is mounted outside on the  casing.

Impeller

The impellers are made of aluminum and are dynamically balanced in accordance with ISO 21940-11, balancing quality G6,3, and vibration limits according to ISO 14694.

Motor

Standard models are driven by three-phase AC motors with efficiency IE3 suitable for 50Hz and optionally for 60Hz.

Motor protection

The motors can be equipped with PTC thermistors for motor protection (on request).

Control

Motors can be speed controlled by frequency inverter between 10 and 60 Hz.

Installation

The AXC(F)-G fans can be installed in different positions indoor and outdoor, outside or inside of fire zone (for more information see the manual).

Recommended accessories: flexible connections, vibration dampers, mounting feet.