IF 100 Q Inline fan #254510
Ideal for extraction of air in bathroom, toilet and small/medium premises. Suitable to extract stale air directly to the outside or through shortlength ducting. Casing made of high quality ABS provides long lasting shock-proof and robust construction. The unit is finished in white RAL 9010 and areUV resistant. Unique design winglet-type impeller, providing enhanced aerodynamic properties, low noise and increased efficiency. Single-phase induction motors with integral thermal protection, mounted on sealed for life high quality sleeve bearings.Suitable for continuous and intermittent running.
230V 1~ 50Hz | |||
---|---|---|---|
Nominal data | |||
Voltage (nominal) | 230 | V | |
Rated voltage | 220 to 240 | V | |
Frequency | 50 | Hz | |
Phases | 1~ | ||
Input power | 8 | W | |
Input power kW | 0.008 | kW | |
Input current | 0.068 | A | |
Impeller speed | 2,230 | rpm | |
Air flow | 0 to 84 | m³/h | |
Temperature of transported air | max 50 | °C | |
Sound data | |||
Sound pressure level at 3m (free field) | 34 | dB(A) | |
Protection/Classification | |||
Enclosure class, motor | IPX4 | ||
Insulation class | B | ||
Data according to ErP | |||
Energy class, Basic unit | C | ||
Energy class, Local demand | E | ||
ErP ready | ErP 2018 | ||
Dimensions and weights | |||
Duct dimension; Circular, inlet | 100 | mm | |
Weight | 0.36 | kg | |
Others | |||
Motor type | AC |
230V 1~ 50Hz | |||
---|---|---|---|
Ecodesign | |||
ErP compliance | 2018 | ||
Unit category | RVU | ||
Drive | External MSD or VSD | ||
Unit type | UVU | ||
Heat recovery type | None | ||
Temperature ratio (UVU) | Not applicable | ||
qv nom | 0.0163 | m³/s | |
P nom | 0.008 | kW | |
Ps nom | 13 | Pa | |
Fan efficiency | 2.5 | % | |
Basic unit | |||
ErP compliance | 2018 | ||
SEC Average | -10.75 | kWh/(m².a) | |
SEC Cold | -27.16 | kWh/(m².a) | |
SEC Warm | -1.61 | kWh/(m².a) | |
SEC Class | E | ||
Unit category | RVU | ||
Unit type | UVU | ||
Drive | External MSD or VSD | ||
Heat recovery type | None | ||
Temperature ratio (UVU) | Not applicable | ||
qv max | 59 | m³/h | |
P max | 8 | W | |
qv ref | 0.0114 | m³/s | |
Ps ref | 50 | Pa | |
SPI | 0.204 | W/(m³/h) | |
CTRL | 1 | ||
MISC | 1.1 | ||
x-value | 1.5 | ||
External Leakage | Not applicable | ||
AEC average | 256 | kWh | |
AHS Cold | 256 | kWh | |
AEC warm | 256 | kWh | |
AHS Average | 17 | kWh/a | |
AHS Warm | 8 | kWh/a | |
Units with local demand control | |||
ErP compliance | 2018 | ||
SEC Average | -24.95 | kWh/(m².a) | |
SEC Cold | -52.01 | kWh/(m².a) | |
SEC Warm | -9.44 | kWh/(m².a) | |
SEC Class | C | ||
Unit category | RVU | ||
Unit type | UVU | ||
Drive | External MSD or VSD | ||
Heat recovery type | None | ||
Temperature ratio (UVU) | Not applicable | ||
qv max | 59 | m³/h | |
P max | 8 | W | |
qv ref | 0.0114 | m³/s | |
Ps ref | 50 | Pa | |
SPI | 0.204 | W/(m³/h) | |
CTRL | 0.65 | ||
MISC | 1.1 | ||
x-value | 1.5 | ||
External Leakage | Not applicable | ||
AEC average | 134 | kWh | |
AEC cold | 134 | kWh | |
AEC warm | 134 | kWh | |
AHS Average | 28 | kWh/a | |
AHS Cold | 55 | kWh/a | |
AHS Warm | 13 | kWh/a |