50-220 kW • R410A • Highly customisable Rooftop units
Three performant energy recovery systems
Wide operating limits
Low energy EC fans (for supply/return air)
A wide range of configuration options
Precise and complete selection on AC SELECT
Important: Check ErP compliance according to the configurations on AC SELECT.
The SYSAER rooftop units comes with a number of customisation options and accessories, ensuring there is a SYSAER that will meet every project requirement.
Coming with extended operating limits means your SYSAER units will work perfectly well no matter how harsh the weather or climate. For excellent performance all year round, these units operate under temperatures comprises between -15°C to +50°C.
RECO → Standard energy RECOvery (3 Dampers) : Energy recovery on the exhaust air
TRECO → Thermodynamic energy RECOvery (3 Dampers) : Active energy recovery between the exhaust air and the fresh air using a dedicated thermodynamic system
FRECO → Food refrigeration energy RECOvery : In supermarkets, FRECO technology allows our rooftop units to recover the heat generated out from the condensers of the cooling systems.
SYSAER rooftop units are available in 10 sizes and in cooling-only (L) or reversible (H) versions. They operate with R410A refrigerant and two independent circuits completely closed in a separate compartment.
Each unit is equipped with AC or EC plug fans (for supply/extract air), Scroll compressor(s), finned coil heat exchangers and large removable panels allowing a great accessibility to internal components for service operations.
The range also offer different types of filtration (G4, G4+F7, G4+F9), several configuration options (No damper, 2 dampers, 3 dampers) and many accessories.
The cabinet and structure are of heavy duty galvanized steel components, individually painted (RAL 7040) before the assembly for a homogeneous protection against corrosion. Double skin panels ensure a perfect thermal insulation (25mm glasswool – 63Kg/m3).
The control system is wired, tested and shipped READY TO USE. An external control panel displays the operating parameters and alarms.
EUROVENT certification : sizes 55 to 95
Eurovent Certified Performance es la prueba de rendimiento global en la certificación HVACR, la marca garantiza que este producto funciona como anunciado. Comprueba la validez de nuestros certificados en https://www.eurovent-certification.com
Unidad | |||
---|---|---|---|
Número de tamaños | 10 | ||
Tipo de intercambiador de calor del lado del aire | Tubos finalizados | ||
Rendimientos | |||
Capacidad de enfriamiento | 48,1 Para 219,12 | kW | |
Capacidad de calentamiento | 50,65 Para 214,37 | kW | |
Capacidad de calefacción (máx.) | 214,37 | kW | |
Datos generales | |||
Tipo de refirgerante | R410A | ||
Frecuencia | 50 | Hz | |
Fases | 3N~ | ||
Tensión (nominal) | 400 | V | |
Tipo de compresor | scroll |