OPTIMA-R-LPC_BMOPTIMA-R-LPC-80-BM-S

OPTIMA-R-LPC_BM Muutuva õhuhulga regulaatorid

Ruumide õhurõhu regulaator

  • Kompaktne

  • Tsingitud teras

  • Tehases kalibreeritud

  • Vähene müra

OPTIMA-R-LPC-80-BM-S#338717
978,67 €käibemaksuta
või loo konto online tellimiseks
Systemair DESIGN selection tool

Tsingitud teras

OPTIMA-R-PC...BM AV-seadme korpus on valmistatud tsingitud terasplekist, mis muudab selle vastupidavaks.

Tehases kalibreeritud

Regulaatorid on standardselt kalibreeritud tehases tabelis näidatud õhumahule või soovi korral saab neid enne lähetamist kohandada vastavalt soovitud seadetele.

OPTIMA-R-LPC...BM on reguleeritav madalrõhu regulaator koos isolatsiooniga või ilma. Seda kasutatakse tavaliselt õhurõhu reguleerimiseks ruumis ja see on saadaval erinevates suurustes. OPTIMA-R-LPC...BM paigaldatakse tavaliselt kontorites, avalikes ruumides, laborites, tööstusettevõtetes ja tervishoiuruumides.

VAV-seadme korpus on valmistatud tsingitud terasplekist. Regulaatorid on standardselt kalibreeritud tehases vaikimisi õhurõhu järgi või soovi korral saab neid enne saatmist kohandada vastavalt kohapeal nõutavatele seadistustele Pmin ja Pmax vahemikus. See tuleb enne seadme tellimist teatada, et tagada piisav kalibreerimine tehases. Võimalik on pakkuda Gateway sideüksusi, mida saab hiljem ühendada hoone juhtimissüsteemidega.

Sertifikaadid

Laeb...

Tehnilised andmed

Tehnilised andmed

Artikli nimi
OPTIMA-R-LPC-80-BM-S
Artikli number
#338717
Nominaalandmed
Communication data1xAI, 1xAO, 2x(NO/NC, pot. free)
Toruühenduse tüüpÜmar
Pinge (Nominaal)24V
Elektritarve juhtmes2VA
Mõõtmed ja kaal
Kaal1.7kg

Spetsifikatsioon

Round variable pressure regulator for regulating the air pressure in areas covered by a ventilation system.It can be used for supply and exhaust air and is available in 15 sizes (DN 080–630 mm).The control components are assembled and wired at the factory.The connection pieces have lip seals on both sides and are suitable for air ducts according to EN 1506 or EN 13180.The damper position can be read from the axis.Leakage air rate with closed damper according to EN 1751, Class 4.Housing leakage air rate according to EN 1751, Class C.Actuators 24 VPressure control range up to +/- 75 PaFor measuring/controlling the supply or exhaust air pressure difference between room and atmosphereHigh measurement/control accuracy of 5%Static sensor for taking measurements, even in dusty atmospheresInsulated version to reduce radiated noiseEach controller is calibrated and adjusted at the factory.Controller with analog, BACnet, and MODBUS communication as standardMaterials and surfacesHousing and damper are made of galvanized sheet steelSeals on pipe connections and butterfly discPlain bearings made of plasticsOptionally with insulation under lagging section made of galvanized sheet steel.Insulation made of NBR/PVC (according to EN 13501-1) building material group B-s3, d0Technical specificationNominal sizes: 080–630 mmAttachmentsS – standard driveQ – Actuator with short transition time (high-speed actuator)QE – Actuator with short transition time (high-speed actuator) and electrical safety functionF – Actuator with mechanical safety function (spring return)Required separate accessories:– Pilot tube, maximum length 10 m– Pilot-tube-duct connector– Hose clamp for securing (optional) - Size: 80- Insulation: Without insulation- Equipment, Communication type: S: Standard actuator with transition time 120 s- Electrical Connections: AC/DC 24 V, modulating (VAV)- Airflow direction: Supply