Systemair Compact-Line units are designed as a compact air handling units, manufactured according to the Ecodesign Directive, Machinery Directive, Low Voltage Directive, EMC Directive and other directives covering functional elements. Essential requirements, stated in the standards EN 1886, EN 13053, EN 16798-3 and VDI 6022, have been accounted. Adjustments in order to meet the requirements of other standards are also possible. Units can be selected with airCalc++ selection tool, which is frequently updated and allows optimization of every option.The preconfigured standard version units are made in accordance with the general technical, safety and hygienic requirements which are laid down by the EU and domestic rules, regulations and standards. Quality, optimization, reliability and efficient calculation ensures the best performance with a low pressure loss that is crucial for the safe operation and energy efficiency of the units.EUROVENT certified.The Compact Line series is available in 5 sizes with a nominal air flow of up to 8000 m3/h, with both plate and rotary heat exchanger.Mechanical properties in accordance with EN 1886:

  • Thermal transmittance class T2
  • Thermal bridging class TB2 
  • Mechanical strength casing class D1
  • Casing air leakage class L1 / L2

Available in indoor and outdoor versions

Indoor unit (Standard casing materials)
  • casing frame is made of aluminium EN AW-6060 (AlMgSi) quality with interrupted thermal bridge and corner pieces made of nylon (PA6+GF20%) reinforced with fiberglass 
  • internal panel sheet is made of ZnAlMg coated steel 
  • internal fastening material is made of ZnAlMg coated steel
  • external panel sheet is made of ZnAlMg coated steel
  • external fastening material is made of ZnAlMg coated steel
Outdoor unit (Additional protection against outdoor atmospheric conditions)
  • Waterproof roof is made of ZnAlMg coated steel (optionally: galvanized pre-painted steel sheet RAL 9006). The design of the roof closes all possible gaps, prevents any water from accessing the unit from the top and protects the panels.
  • External panel sheet is made of ZnAlMg coated steel (optionally: galvanized pre-painted steel sheet RAL 9006). Panels are installed with Ruspert protected screws. Other fastening material is Ruspert protected or stainless steel.
  • Weather protection hoods is made of ZnAlMg coated steel (optionally: galvanized pre-painted steel sheet RAL 9006). They protect the outdoor and exhaust air openings. There are no sharp edges on the hood that could injure people. Drainage channels keep water on the outer side of the weather hood, so it has no chance to enter unit trough outdoor opening. A protective steel grille is installed on each opening, preventing the entry of small animals, leaves or other nuisances. 
  • The dampers with the actuator are always placed inside the casing, allowing extra protection of actuator and electric parts, 
  • The heating and cooling coils are designed with external collecting pipe connections.  It is necessary to protect the hydraulic circuit from external weathering and from freezing conditions during winter.
 All units are controlled by the Systemair Access control system, which allows all operating functions to be monitored, including via the bms system. Quick selection and thermodynamic calculation of the unit can be made in airCalc++. By using this application we can provide useful information about the unit such as:
  • technical data for all modules,
  • heat recovery and coil calculations,
  • energy consumption,  
  • acoustics information,
  • detailed technical drawings, dimensions and weights,
  • Mollier diagram,
  • prices.
 