BF QWBF 100 QW Bathroom fan

BF QW Domestic Fans

Bathroom fan for installation in windows

  • Robust. IPX4 protection degree

  • Installation directly to the windows

  • Low power consumption

  • Integral back-draught shutter


BF 100 QW Bathroom fan#254516
Frequency: 50 Hz

Flexible

The unobtrusive design of BF QW, integrated window kit and simple control allows it, to be used in bathrooms, toilets and small/medium premises.

Durable

Each unit is built from robust, durable components and suitable for continuous and intermittent running even in cold climates. Fans are fully recyclable once it has reached the end of its operational lifespan.

Tehničke specifikacije

Karakteristike

Construction

Casing made of high quality ABS provides long lasting shock-proof and robust construction with IPX4 protection degree. The unit is finished in white RAL 9010 and are UV resistant. Fan has integral back-draught shutter to prevent air flowing back into the room when the fan is off.

Impeller

Special design winglet-type axial impeller, providing enhanced aerodynamic properties, low noise and high efficiency.

Motor

Single-phase induction AC motors, mounted on sealed for life, high quality sleeve bearings. Suitable for continuous and intermittent running. All motors are suitable for 50Hz and 60Hz.

Motor protection

BF QW fan motors have integrated thermal protection.

Control

All BF QW fans can be manually operated via a separate ON/OFF switch or the light switch.

Installation

Fan can be installed on wall/panel or window. Window kit included to simplify installation process.

Fan is double insulated: no earth connection is required when connecting to the power source.

Tehnički podatci

Naziv proizvoda
BF 100 QW Bathroom fan
Broj proizvoda
#254516
230V 1~ 50Hz
Nominal data
Voltage (nominal)230V
Frequency50Hz
Phases1~
Input power11W
Input power kW0.011kW
Input current0.069A
Impeller speed2,230rpm
Air flowmax 78m³/h
Temperature of transported airmax 50°C
Sound data
Sound pressure level at 3m (free field)33dB(A)
Protection/Classification
Enclosure class, motorIPX4
Insulation classB
Data according to ErP
Energy class, Basic unitC
Energy class, Local demandF
ErP readyErP 2018
Dimensions and weights
Duct dimension; Circular, inlet100mm
Weight0.81kg
Others
Motor typeAC

Ecodesign

230V 1~ 50Hz
Ecodesign
ErP compliance2018
Unit categoryRVU
DriveExternal MSD or VSD
Unit typeUVU
Heat recovery typeNone
Temperature ratio (UVU)Not applicable
qv nom0.0151m³/s
P nom0.01kW
Ps nom12Pa
Fan efficiency1.7%
Basic unit
ErP compliance2018
SEC Average-8.59kWh/(m².a)
SEC Cold-24.99kWh/(m².a)
SEC Warm0.8kWh/(m².a)
SEC ClassF
Unit categoryRVU
Unit typeUVU
DriveExternal MSD or VSD
Heat recovery typeNone
Temperature ratio (UVU)Not applicable
qv max54m³/h
P max10W
qv ref0.0106m³/s
Ps ref50Pa
SPI0.273W/(m³/h)
CTRL1
MISC1.1
x-value1.5
External LeakageNot applicable
AEC average342kWh
AHS Cold342kWh
AEC warm342kWh
AHS Average17kWh/a
AHS Warm8kWh/a
Units with local demand control
ErP compliance2018
SEC Average-32.81kWh/(m².a)
SEC Cold-50.88kWh/(m².a)
SEC Warm-8.31kWh/(m².a)
SEC ClassC
Unit categoryRVU
Unit typeUVU
DriveExternal MSD or VSD
Heat recovery typeNone
Temperature ratio (UVU)Not applicable
qv max54m³/h
P max10W
qv ref0.0106m³/s
Ps ref50Pa
SPI0.273W/(m³/h)
CTRL0.65
MISC1.1
x-value1.5
External LeakageNot applicable
AEC average179kWh
AEC cold179kWh
AEC warm179kWh
AHS Average28kWh/a
AHS Cold55kWh/a
AHS Warm13kWh/a

Značajke