CLEVA500-D-IDA2-CO2-DPT

CLEVA Air Handling Units

CLEVA500-D-IDA2-CO2-DPT#64556000

CLEVA500-D-IDA2-CO2-DPT #64556000

Systemair’s Cleva heat recovery units are designed for false ceiling installation, offering an efficient and compact solution for ventilation and air treatment in various environments. Available in six sizes, with airflow rates ranging from 500 to 4,000 m³/h, these units ensure high performance in spaces with installation constraints. Built with corrosion-resistant materials in compliance with ISO 12944 category C5, Cleva units guarantee a long service life, even in demanding conditions. Additionally, they feature integrated control systems that optimize operation and simplify maintenance.Thanks to their compact design and versatility, Cleva units are an ideal solution for projects where space is a key factor. Their false ceiling installation allows for maximum use of the building’s usable area without compromising efficiency or comfort. To facilitate the selection of the most suitable unit for each application, Systemair provides a specialized calculation tool that enables configuration based on airflow, external pressure, and other operational parameters. 

Tech specs

Technical Data

Article name
CLEVA500-D-IDA2-CO2-DPT
Article number
#64556000
Dimensions and weights
Weight91kg

Performance

 Units of measurementCleva 500 Cleva 1000 Cleva 1500 Cleva 2000 Cleva 3000 Cleva 4000
Technical data
       
Article name
  CLEVA-500 Left/CLEVA-500 Right CLEVA-1000 Left/CLEVA-1000 Right CLEVA-1500 Left/CLEVA-1500 Right CLEVA-2000 Left/CLEVA-2000 Right CLEVA-3000 Left/CLEVA-3000 Right CLEVA-4000 Left/CLEVA-4000 Right
Article number
  64559050/64559051 64559100/64559101 64559150/64559151 64559200/64559201 64559300/64559301 64559400/64559401
        
Unit
       
Frequency
Hz 50 - 60 50 - 60 50 - 60 50 - 60 50 - 60 50 - 60
Voltage (nominal)
V 230 230 230 230 230 400 Vac
Phases
  1N~ 1N~ 1N~ 1N~ 1N~ 3N~
Recommended fuse, unit
  1Nx5,1A 1Nx5,2A 1Nx7,3A 1Nx11,1A 1Nx17,8A 3Nx10,6A
        
Supply fan
       
Fan type
  EC EC EC EC EC EC
Voltage
V 230 230 230 230 230 230
Phases
  1~ 1~ 1~ 1~ 1~ 3~
Input power (P1), supply fan
W 170 170 500 780 1300 2400
        
Exchanger
       
Exchanger type
  Counter flow Counter flow Counter flow Counter flow Counter flow Counter flow
Diptray
  Sloped Sloped Sloped Sloped Sloped Sloped
        
Return fan / Extract fan
       
Fan type
  EC EC EC EC EC EC
Voltage
V 230 Sloped 230 230 230 230
Phases
  1~ 1~ 1~ 1~ 1~3~
Input power (P1), supply fan
W 170 170 500 78013502400
Others
       
Fan control
  CAV constant airflow; VAV variable airflow; Voltage Control 0-100% CAV constant airflow; VAV variable airflow; Voltage Control 0-100% CAV constant airflow; VAV variable airflow; Voltage Control 0-100% CAV constant airflow; VAV variable airflow; Voltage Control 0-100% CAV constant airflow; VAV variable airflow; Voltage Control 0-100% CAV constant airflow; VAV variable airflow; Voltage Control 0-100%
Installation type
  Horizontal Horizontal Horizontal Horizontal Horizontal Horizontal
Supply side
 Depending on the location of the electrical panel and direction of the supply air flow.Depending on the location of the electrical panel and direction of the supply air flow.Depending on the location of the electrical panel and direction of the supply air flow.Depending on the location of the electrical panel and direction of the supply air flow.Depending on the location of the electrical panel and direction of the supply air flow.Depending on the location of the electrical panel and direction of the supply air flow.
        
Dimensions and weights
       
Weight
kg91135197247362444
        
        
Ecodesign
       
ErP compliance
 201820182018201820182018
Unit category
  NRVU NRVU NRVU NRVU NRVU NRVU
Unit type
  ERV ERV ERV ERV ERV ERV
Drive
 Integrated VSDIntegrated VSDIntegrated VSDIntegrated VSDIntegrated VSDIntegrated VSD
Other
       
Temperature efficiency Summer/Winter
% 82,4 / 82,6 81,5 / 81,8 78,8 / 79,078,9 / 79,1 82,2 / 82,4 82,1 / 82,4
QV nom
m/h5008001500200030004000
P nom
W209320703104714132294
P nom Supply fan
W1091693685437351182
P nom Extract fan
W1001513355046781112
SFP internal
W/(m³/s)10919521253130811481255
SFP internal Sup
 588515667691616685
SFP internas Ext
 503437586617532570
Air speed through internal section
m/s2,071,962,582,572,422,46
PS nom (PED/ESP) Supply
Pa278249428441387421
PS nom (PED/ESP) Extract
Pa238213368390331345
Supply Fan efficiency
%47,348,463,063,862,861,5
Extract fan efficiency
%47,448,762,863,262,260,6
External Leakage
  L3 L3 L3 L3 L3 L3
Internal Leakage
  L3 L3 L3 L3 L3 L3
Sound power (LWA)
dB(A)8283    
CLEVA #64556000, Performance

Dimensions

CLEVA #64556000, Dimensions

Specification

Systemair’s Cleva heat recovery units are designed for false ceiling installation, providing an efficient solution for ventilation with energy recovery in buildings with space constraints. Available in six sizes, with airflow rates ranging from 500 to 4,000 m³/h, they are built with corrosion-resistant materials in compliance with ISO 12944 category C5, ensuring a long service life even in demanding environments. They feature an integrated control system that optimizes performance and simplifies operational management. Each Cleva unit is equipped with high-efficiency heat exchangers that recover energy from the extracted air, reducing the HVAC system’s energy consumption. Their compact design allows for installation in confined spaces without compromising accessibility for maintenance. Additionally, Systemair provides a selection tool that enables unit configuration based on project requirements, considering parameters such as airflow, available pressure, and climatic conditions. 

Documentation