TLP125/1,2 Air handl.unit

TLP Insulated duct fans

Insulated supply unit with integrated filtration and heating

  • Compact design

  • Insulated casing for low noise 

  • Integrated filtration and heating

  • Easily removable inspection cover 

TLP 125/1,2 Air handl.unit#1870
Frequency: 50/60 Hz

Compact Size

The TLP series of supply units consisting of a fan, heater and filter in a single compact in size insulated casing, making them suitable for various different domestic and commercial applications.

Low Noise Level

In addition to the own casing for fan and heater, TLP has the external casing insulated with 50 mm mineral wool to ensure low level of radiated sound and provide acoustic comfort when it is installed inside the premises.

Air quality under control

Integrated coarse filter increases the quality of the supply air removing large particles out of outdoor air while the integrated heater allows to maintain supply air temperature on desired level.

Easy to maintain

The TLP unit is simple to clean. Easy removable inspection cover and internal connection with fast clamps allows to remove and replace internal parts easily.

Tech specs

Features

Casing

Casing of the TLP supply unit made of galvanised sheet steel corrosion class C3 and insulated with 50mm of mineral wool. TLP has cirular rubber-sealed sleeve couplings, to simplify connection to the circular ducts. Neoprene sealing strips and toggle locks allows to secure inspection lid and prevent leakages.

Fan

TLP uses fan with own casing manufactured from galvanised sheet steel. Fan has backward curved radial impeller made of lightweight, hard-wearing fiberglass reinforced polyamide, dynamically balanced and paired with corresponding external rotor AC motor, which protected from overheating by integrated thermal protection with manual (electrical) reset.

The fan must always be connected to power supply 230V 1~ (50-60Hz).

Heater

Heater inside TLP unit has own casing manufactured from Aluzinc-coated sheet steel with a heating element in stainless steel.

The heater has integral 2 step overheating protection: one with automatic reset and one with manual reset. Additional protection can be done by using pressure relay DTV200 installed as flow guard.

Filter

All TLP supply units supplied with plate filter class Coarse 60% (G4). Filter has rigid perimetral frame to simplify installation and obtain required internal leakage level. The filter should be inspected regularly and replaced at least twice a year.

Control

Airflow level can be controlled by andjusting fan speed 5-step or stepless speed regulator (external accessory).

For temperature control, the heater is most effectively can be controlled by an external power regulator, Pulser-M or Optigo OP and duct temperature sensor. The unit has a maximum air output temperature of 40°C. Fan run-on is not normally required.

Installation

TLP is recommended to install indoor on the floor with inspection lead on top.

Small sizes up to 200 can be also installed upside down (inspection lid to the bottom) in false ceilings. In this case the heater must be placed according to installation manual.

Circular spigot with rubber seals designed to connect TLP to the circular ducts by using fast clamps preventing vibration transfer to the duct system.

Technical Data

Article name
TLP 125/1,2 Air handl.unit
Trade name
Systemair
Article number
#1870
230V 1~ 50Hz
Unit
Frequency50Hz
Voltage (nominal)230V
Phases1~
Enclosure classIP44
Speed regulationTransformer
Air flow70 to 130m³/h
Product typeSupply unit
Supply fan
Voltage230V
Phases1~
Current0.159A
Input power (P1), supply fan29W
Impeller speed2,571rpm
Max. Temperature of transported air, when speed controlled70°C
Insulation classB
Supply air filter
Filter class, supply airCoarse 60%
Heater
Current, electrical heating battery5.22A
Input power, heater1.2kW
Connections
Duct dimension; Circular, inlet125mm
Dimensions and weights
Weight31.5kg
Sound data
Sound pressure level at 3m (20m² Sabin)29dB(A)
ERP
Energy class, Basic unitF
Energy class, Local demandC
ErP readyErP 2018

Ecodesign

230V 1~ 50Hz
Units with local demand control
ErP compliance2018
SEC Average-23.5kWh/(m².a)
SEC Cold-50.5kWh/(m².a)
SEC Warm-7.8kWh/(m².a)
SEC ClassC
Unit categoryRVU
Unit typeUVU
DriveExternal MSD or VSD
Heat recovery typeNone
Temperature ratio (UVU)Not applicable
qv max193m³/h
P max27W
Sound power (LWA)37dB(A)
qv ref0.0269m³/s
Ps ref50Pa
SPI0.294W/(m³/h)
CTRL0.65
MISC1.1
x-value1.5
External Leakage5%
AEC average193kWh
AEC cold193kWh
AEC warm193kWh
AHS Average28kWh/a
AHS Cold55kWh/a
AHS Warm13kWh/a
Basic unit
ErP compliance-
SEC Average-kWh/(m².a)
SEC Cold-kWh/(m².a)
SEC Warm-kWh/(m².a)
SEC Class-
Unit category-
Unit type-
Drive-
Heat recovery type-
Temperature ratio (UVU)-
qv max-m³/h
P max-W
Sound power (LWA)-dB(A)
qv ref-m³/s
Ps ref-Pa
SPI-W/(m³/h)
CTRL-
MISC-
x-value-
External Leakage-%
AEC average-kWh
AEC cold-kWh
AEC warm-kWh
AHS Average-kWh/a
AHS Cold-kWh/a
AHS Warm-kWh/a

Performance

Dimensions

TLP #1870, Dimensions
A
436
B
211
C
459
D
465
E
786
F
745
øG
125
H
740