Compact centrifugal roof fan for domestic and commercial applications
Compact low-profile design
Easy maintenance with integrated tilting mechanism
Vertical exhaust to prevent wet, snow and staining of the roof
The TFE fan combines a small physical footprint with power and efficiency and suitable for use in exhaust-air ventilation systems, in single and multiple dwellings, offices and day nurseries.
The unit’s vertical design ensures that no issues arise from air ventilation. This prevents the issues related to the melting of snow or around heavy rain or staining of the roof.
Swing-out design of the fan together with integrated tilting mechanism allows to keep maintenance process as easy as possible.
Casing made of galvanised sheet steel and additionally protected by powder-coating in standard black colour. The TFE casing includes a ‘swing out’ design to simplify maintenance and integrated tilting mechanism to provide easy access. To simplify the wiring process, the fan is also equipped with a 1 m long cable.
Backward curved radial impellers made of lightweight, hard-wearing fiberglass reinforced polyamide, dynamically balanced and paired with corresponding external rotor motors.
TFE fans are equipped with AC external rotor motors insulation class B, supported by long-life ball bearings.
TFE fans have an integrated thermal protection with manual (electrical) reset.
TFE fans are controlled by 5-step or stepless speed regulator provided as accessory. Speed regulation can be combined with timer, thermostat, hygrostat, etc. by using wide range of electrical accessories.
The TFE must be installed on the roof in horizontal position. We recommend to install the fan together with a roof curb (available as an accessory).
230V 1~ 50Hz | |||
---|---|---|---|
Nominal data | |||
Voltage (nominal) | 230 | V | |
Frequency | 50 | Hz | |
Phases | 1~ | ||
Input power | 107 | W | |
Input power kW | 0.107 | kW | |
Input current | 0.468 | A | |
Impeller speed | 2,602 | rpm | |
Air flow | max 788 | m³/h | |
Capacitance of capacitor | 3 | µF | |
Temperature of transported air | max 70 | °C | |
Max temperature of transported air, when speed controlled | 70 | °C | |
Sound data | |||
Sound pressure level at 10m (free field) | 38 | dB(A) | |
Protection/Classification | |||
Enclosure class, motor | IP44 | ||
Insulation class | B | ||
Data according to ErP | |||
Energy class, Basic unit | E | ||
Energy class, Local demand | B | ||
ErP ready | ErP 2016; ErP 2018 | ||
Dimensions and weights | |||
Weight | 8 | kg | |
Others | |||
Color name, casing | Black | ||
Motor type | AC |
230V 1~ 50Hz | |||
---|---|---|---|
Product | |||
Trade name | Systemair | ||
Product name | TFE 220 M Roof fan | ||
Basic unit | |||
ErP compliance | 2016 | ||
SEC Average | -13.1 | kWh/(m².a) | |
SEC Cold | -29.5 | kWh/(m².a) | |
SEC Warm | -3.7 | kWh/(m².a) | |
SEC Class | E | ||
Unit category | RVU | ||
Unit type | UVU | ||
Drive | External MSD or VSD | ||
Heat recovery type | None | ||
Temperature ratio (UVU) | Not applicable | ||
qv max | 644 | m³/h | |
P max | 100 | W | |
Sound power (LWA) | 57 | dB(A) | |
qv ref | 0.125 | m³/s | |
Ps ref | 50 | Pa | |
SPI | 0.128 | W/(m³/h) | |
CTRL | 1 | ||
MISC | 1.1 | ||
x-value | 1.5 | ||
External Leakage | 0 | % | |
AEC average | 160.3 | kWh | |
AHS Cold | 160.3 | kWh | |
AEC warm | 160.3 | kWh | |
AHS Average | 1,715.2 | kWh/a | |
AHS Warm | 775.6 | kWh/a | |
Units with local demand control | |||
ErP compliance | 2018 | ||
SEC Average | -26.2 | kWh/(m².a) | |
SEC Cold | -53.3 | kWh/(m².a) | |
SEC Warm | -10.7 | kWh/(m².a) | |
SEC Class | B | ||
Unit category | RVU | ||
Unit type | UVU | ||
Drive | External MSD or VSD | ||
Heat recovery type | None | ||
Temperature ratio (UVU) | Not applicable | ||
qv max | 645 | m³/h | |
P max | 100 | W | |
Sound power (LWA) | 57 | dB(A) | |
qv ref | 0.1254 | m³/s | |
Ps ref | 50 | Pa | |
SPI | 0.128 | W/(m³/h) | |
CTRL | 0.65 | ||
MISC | 1.1 | ||
x-value | 1.5 | ||
External Leakage | 0 | % | |
AEC average | 84 | kWh | |
AEC cold | 84 | kWh | |
AEC warm | 84 | kWh | |
AHS Average | 2,830 | kWh/a | |
AHS Cold | 5,536.2 | kWh/a | |
AHS Warm | 1,279.7 | kWh/a |