Safe, energy-efficient cooling systems, delivering high profitability with maximum uptime
Cooling: Mission-critical for data centres and server rooms
As global demand for online processes and data transmission skyrockets, the need for building more and more energy-efficient data centres increases.
And if data centres and server rooms are to stay profitable into the future, it’s crucial they align now with the world’s long-term energy and environmental goals.
At Systemair, we provide a range of hard-wearing, high-energy-efficiency cooling solutions that perform their best all year long – with minimal impact on the environment. So you can confidently meet local, national, and international standards for energy efficiency, without compromising your centre’s performance.
Precise and reliable operations
Maximum energy efficiency
Easy maintenance and installation
Long-term sustainability
All Systemair data centre and server room cooling products are pre-tested in our specialised Test Centre to assure their performance under simulated conditions.
Remote Access allows you to see, first-hand, exactly how your solutions will perform – under simulated data centre heat load for even the most challenging outdoor climate conditions, including:
Real server rack simulation up to 500kW load
Outdoor air test conditions from -5 °C to +45 °C
Controls and Alarm simulation testing
The Test Centre is AMCA210 accredited for airflows from 5,000 m³/h to 100,000 m³/h. All measurement techniques used are conducted in accordance with ASHRAE I43-2015.
There are many things we can control – but the weather isn’t one of them. So it doesn’t make sense to have a data centre or server room cooling solution that only functions at its best within a tight range of climate conditions.
Systemair data centre and server room cooling solutions can easily be customised to your application case, ensuring they will operate as efficiently and smoothly as possible, no matter if they’re exposed to extreme heat to extreme cold.
With more and more demand for IT capacities installed in the data centre, there is less space left for technical areas and cooling systems.
Systemair’s cooling solutions come with multiple configuration options, so you can rest assured there is always a smart way to install your units for the smallest possible physical footprint, including:
Walkable Clusters which can be accessed from the inside for servicing
Lego principle clusters to save space for service corridors in between units, creating breezing wall systems with even air distribution along the whole installation width
Vertical units for minimal footprint and even “no footprint” solutions with horizontal fan walls
Geniox Tera are designed to meet high requirements for sustainable cooling that is achieved by usage of outdoor air and the natural cooling effect of the water evaporation process.
Considering ASHRAE’s regulations for IT equipment, Geniox Tera units are able to Free-cool all year round in most European locations. In really hot regions, free-cooling can be used in combination with built-in mechanical cooling stage constantly assuring lowest power consumption and minimal environmental impact.
Ultra-efficient free-cooling with no outside air in the data centre
Cooling capacity up to 400 kW
Low pPUE and low water consumption
Water recirculation system and multi-stage water quality control
Minimised or eliminated the need for mechanical cooling
Reduced amount of hours in Wet free-cooling mode and higher water usage efficiency at the same operating conditions
Minimised fan power consumption due to reduced internal pressure drops
Optional Integrated DX cooling circuit
Wide range of Heat recovery solutions
Business-critical hyperscale data centres require cooling solutions that are both energy-efficient to save costs, and reliable – with minimal to zero downtime.
Geniox Tera Direct Free-Cooling Units have been specially developed for hyper-scale data centre cooling applications. With minimal footprints, the lowest pPUE figures, and modular designs, they deliver incredible performance in almost any configuration.
Highly flexible, compact, and modular for the most efficient use of technical spaces.
Off-the-shelf unit range with cooling capacity up to 400 kW, and customised units with cooling capacity up to 840 kW.
Integrated controls and sensors for easy operation with your choice of ATS and UPS for controls.
Assure minimal pPUE
Have ultra-low OPEX, delivering natural free cooling with no mechanical support
Deliver low air velocity and even air distribution along the data hall and deliver extremely efficient heat exchange due to reduced internal velocities
Comes with an optional heat recovery module and solutions for extremely low outdoor air temperatures
Contact us about Geniox Tera Indirect Free-Cooling Units