Achieve year-round cooling with outdoor air and natural water evaporation processes
Ultra-efficient Cooling with Minimal Environmental Impact
Geniox Tera I units are engineered to deliver ultra-efficient cooling with minimal carbon footprint. Utilising outdoor air and the natural cooling effect of water evaporation, these units offer reliable performance and low energy consumption. Geniox Tera I units are ideal for a range of climates and can operate in free-cooling mode all year round in most European locations. This significantly reduces the need for mechanical cooling.
Cooling capacity up to 300 kW and airflow up to 75,000 m3/h
Highly efficient free cooling without the use of outside air in the data center
Built-in water treatment system
Extensive heat recovery options
The 60 mm thick insulation minimizes heat loss and thermal bridges, allowing energy savings.
The handles, hinges, and inspection windows are designed exclusively for and by Systemair, ensuring a long lifetime.
The latest generation EC fans guarantee the lowest power consumption, as well as precise airflow control and reduced noise levels. Optionally, EC fans can be equipped with harmonic filters.
Specially designed for evaporative cooling
B·Blue coated aluminum fins guarantee high heat transfer efficiency and long-term corrosion resistance.
Turbulent geometry of the fins promotes uniform distribution of water over the entire surface, resulting in increased cooling capacity and reduced water consumption.
Chilled water or direct evaporative (DX) refrigerant coil with copper tubes and aluminum fins as standard. For maximum efficiency and no dehumidification the coils are designed with a sensible heat ratio of 1.
Nozzles design guarantees 100% surface coverage with a smaller amount of water.
AISI 316l stainless steel drain pan
UV lamp for antibacterial treatment
Conductivity control
Built-in water filter reduces water refresh.
A fully integrated control system sets unit capacity by adjusting the DC fan speed according to differential temperature or to differential pressure control. Cooling mode is selected depending on outdoor air conditions. Wide range of communication protocols available.
Optional double power feed intake and UPS battery for controller ensure unitnerruptable work.
With Tera I’s wide range of configurations and options we can meet even the most challenging data center requirements, adapting to various building layouts and outdoor conditions.
Geniox Tera I units are designed for optimal space utilisation. Units are available in both Rooftop and Perimeter configurations.
Optimised design ensures minimal internal pressure drop and air velocity, resulting in the lowest fan power consumption and efficient thermal exchange with outdoor air.
The smart control system prioritises the optimal operating mode, minimising annual power and water consumption based on the data centre’s location, outdoor conditions, and specific requirements.
System uptime is crucial in data centres. Geniox Tera I is designed for fast and easy service access, ensuring cooling with minimal interruption.
Geniox Tera I units comply with ASHRAE regulations for IT equipment, enabling year-round free-cooling in most European areas. In hotter climates, free-cooling can be paired with a cooling coil for optimal energy efficiency and reduced environmental footprint.
At Systemair, we provide complete, tailored cooling solutions for data centers. Recognizing each project's uniqueness, our experienced team identifies the best systems for your needs.
Systemair offers comprehensive services to optimise the performance of your units. We conduct rigorous full load FAT in our advanced laboratory, run or oversee on-site commissioning L2-L5, and provide ongoing service and maintenance for long-term reliability. You can trust us to ensure your units run smoothly and efficiently.