Explosion-proof centrifugal roof fan with vertical discharge
Certified according to ATEX 2014/34/EU
Sizes 315 up to 500 inclusive tilting device
DV-EX roof fans are designed for challenging environments where explosive atmospheres can occur. Which is why they are tested according to ATEX directive 2014/34/EU – to ensure they’ll perform as intended after installation.
The casing made out of seawater resistant aluminium with an inside galvanised steel frame is hard-wearing. This makes the fan also suitable for coastal applications.
The combination of casing and motor construction ensures to minimize the need for maintenance of the fans and allows long continuous operation.
DV-EX could be used for zone 1 and zone 2; Field of application for gases of groups IIA, IIB and also hydrogen, temperature class T1, T2 and T3.
The casing casing is manufactured from sea water resistant aluminium. The base frame is manufactured from galvanised steel and the inlet cone from copper. A powder coated bird guard manufactured from galvanised steel is integrated in the casing.
The DV-EX fans use radial impeller with backward curved blades. These are made out of alluminum, dynamically balanced and paired with corresponding external rotor motors.
Voltage controllable, explosion proof, 3-phase external rotor motor. Separate “Ex-e” connection box available as an accessory.
Integrated PTC thermistors, to be connected to a motor protection device.
Speed controllable by a 5-step transformer
The DVS-EX are for outside installation.
400V 3~ 50Hz | |||
---|---|---|---|
Nominal data | |||
Voltage (nominal) | 400 | V | |
Frequency | 50 | Hz | |
Phases | 3~ | ||
Input power | 120 | W | |
Input power kW | 0.12 | kW | |
Input current | 0.23 | A | |
Impeller speed | 1,340 | rpm | |
Air flow | max 411 | L/s | |
Temperature of transported air | max 40 | °C | |
Max temperature of transported air, when speed controlled | 40 | °C | |
Protection/Classification | |||
Enclosure class, motor | IP44 | ||
Insulation class | F | ||
Explosion proof marking | II 2G Ex h IIB+H2 T3 Gb | ||
Certificate | TPS 20 ATEX 085751 0007 X | ||
Data according to ErP | |||
ErP ready | Not ErP relevant | ||
Ambient and duct temperature | |||
Ambient and duct temperature | -20 to 40 | °C | |
Dimensions and weights | |||
Weight | 18 | kg | |
Others | |||
Motor type | AC |
Roof fan, vertical discharge. Explosion proof version. Casing made of seawater resistant aluminium.Base frame made of galvanised steel sheet, copper inlet cone.With tilting device FTG. Free-running, backward curved centrifugal impeller made of aluminium. Balancing quality G 6.3, dynamically balanced acc. to DIN ISO 1940-1.Voltage controllable external rotor motor, vibration-free mounted, the motor is placed inside the air flow for cooling. PTC. Supply cable, led out.For the extraction of potentially explosive atmosphere of zone 1, category 2G and zone 2, category 3G.Field of application for gases of groups IIA, IIB and hydrogen.Clasification: II 2G Ex h IIB+H2 T3 Gb.Tested acc. to ATEX Directive 2014/34/EU.For outdoor installation. Vertical installation position.