PB-AQUA-B-1-8-500

PB-AQUA

Plenum Box

  • Rectangular 

  • Horizontal/Vertical Versions 

  • Stainless Steel 

  • Optimal Air Distribution


PB-AQUA-B-1-8-500#247049

Optimal Air Distribution

PB-AQUA is a plenum box installed with slot diffuser AQUA of the corresponding dimension to achieve optimal air distribution. 


Horizontal/Vertical Versions

The PB-AQUA is available in 2 versions. PB-AQUA-S with horizontal duct connection on the side.PB-AQUA-B with vertical duct connection on the bottom. 


Stainless Steel

The rectangular plenum box PB-AQUA is made from a stainless steel A316L sheet. 


PB-AQUA is a plenum box that has been designed to be installed with slot diffuser AQUA of the corresponding dimension to achieve optimal air distribution and discharge over the whole length of the diffuser. The box is available in two versions. The PB-AQUA-S features a horizontal duct connection on the side. The PB-AQUA-B has a vertical duct connection on the bottom. 

The rectangular plenum box PB-AQUA is made from a stainless steel A316L sheet. The air duct connections on the side of the box feature a rectangular or circular shape dependent on the diffuser capacity. The connections on the box are localized in regular distances, the first one 250 mm from the edge of the box, and the following connections are 500 mm from each other. The connections are flat without a gasket. The duct connections are equipped with dampers. 


Certifications

Loading...

Tech specs

Technical Data

Article name
PB-AQUA-B-1-8-500
Article number
#247049
Dimensions and weights
Weight2.34kg

Dimensions

Specification

Junction box for the slotted outlet in swimming pools and wet areas. Matches the corresponding slotted outlets with 1 to 5 slots and slot widths of 8, 10, or 12 mm and a length from 500 mm to 2000 mm.The connection pieces can be installed on the side or vertically.They are made of A316L stainless steel. Depending on the flow capacity, the air connections on the side of the box are round or rectangular. The air connections on the box are arranged at regular intervals, the first is located 250 mm from the edge of the box and each following connection is 500 mm apart from the previous connection. The air connections are flat and have no seal. The duct connections are equipped with an adjustment device. The box with a side connection has a sloping bottom and drainage holes that are closed with removable plugs/ The discharge tubes can also be inserted into the drainage holes. - Connection position: Plenum box with bottom connection- Number of Slots: 1- Slot width: 8 mm- Length: 500 mm