Inline power for bathrooms, wetrooms and more.
Robust
Efficient
Reduced Noise
Compliant
Each unit is fully eco-compliant, ensuring that it´s environmentally conscious and effective.
The casing is made from hard-wearing ABS and finished with white RAL 9010.
Reduced noise level and reduced form factor make it suitable for domestic environments with high footfall.
The IF inline fan series supports use in domestic environments including bathrooms, toilets, shower rooms and other similar locations. Suitable for medium to small-sized premises, units provide air extraction through short length ducting and are built around a 230v PPX4 enclosure class motor.
All units follow a 2018 ErP compliant eco-design for maximum efficiency. The range’s casing is fashioned from high-quality ABS to ensure that it is shockproof and provides long-lasting support for the continuous domestic operation.
Units are also UV resistant and deploy single-phase induction motors with integrated thermal protection to prevent unnecessary damage and eliminate unnecessary wear and tear.
The series is designed for continuous and intermittent use. This is supported by an aerodynamic winglet-type impeller that adds efficiency and reduces noise in areas with high footfall.
230V 1~ 50Hz | |||
---|---|---|---|
Nominal data | |||
Voltage (nominal) | 230 | V | |
Rated voltage | 220 to 240 | V | |
Frequency | 50 | Hz | |
Phases | 1~ | ||
Input power | 15 | W | |
Input power kW | 0.015 | kW | |
Input current | 0.105 | A | |
Impeller speed | 2,230 | rpm | |
Air flow | 0 to 163 | m³/h | |
Temperature of transported air | max 50 | °C | |
Sound data | |||
Sound pressure level at 3m (free field) | 39 | dB(A) | |
Protection/Classification | |||
Enclosure class, motor | IPX4 | ||
Insulation class | B | ||
Data according to ErP | |||
Energy class, Basic unit | C | ||
Energy class, Local demand | E | ||
ErP ready | ErP 2018 | ||
Dimensions and weights | |||
Duct dimension; Circular, inlet | 120 | mm | |
Weight | 0.51 | kg | |
Others | |||
Motor type | AC |
230V 1~ 50Hz | |||
---|---|---|---|
Ecodesign | |||
ErP compliance | 2018 | ||
Unit category | RVU | ||
Drive | External MSD or VSD | ||
Unit type | UVU | ||
Heat recovery type | None | ||
Temperature ratio (UVU) | Not applicable | ||
qv nom | 0.0295 | m³/s | |
P nom | 0.015 | kW | |
Ps nom | 26 | Pa | |
Fan efficiency | 5.1 | % | |
Basic unit | |||
ErP compliance | 2018 | ||
SEC Average | -11 | kWh/(m².a) | |
SEC Cold | -27.4 | kWh/(m².a) | |
SEC Warm | -1.61 | kWh/(m².a) | |
SEC Class | E | ||
Unit category | RVU | ||
Unit type | UVU | ||
Drive | External MSD or VSD | ||
Heat recovery type | None | ||
Temperature ratio (UVU) | Not applicable | ||
qv max | 106 | m³/h | |
P max | 15 | W | |
qv ref | 0.0206 | m³/s | |
Ps ref | 50 | Pa | |
SPI | 0.196 | W/(m³/h) | |
CTRL | 1 | ||
MISC | 1.1 | ||
x-value | 1.5 | ||
External Leakage | Not applicable | ||
AEC average | 246 | kWh | |
AHS Cold | 246 | kWh | |
AEC warm | 246 | kWh | |
AHS Average | 17 | kWh/a | |
AHS Warm | 8 | kWh/a | |
Units with local demand control | |||
ErP compliance | 2018 | ||
SEC Average | -25.08 | kWh/(m².a) | |
SEC Cold | -52.14 | kWh/(m².a) | |
SEC Warm | -9.57 | kWh/(m².a) | |
SEC Class | C | ||
Unit category | RVU | ||
Unit type | UVU | ||
Drive | External MSD or VSD | ||
Heat recovery type | None | ||
Temperature ratio (UVU) | Not applicable | ||
qv max | 106 | m³/h | |
P max | 15 | W | |
qv ref | 0.0206 | m³/s | |
Ps ref | 50 | Pa | |
SPI | 0.196 | W/(m³/h) | |
CTRL | 0.65 | ||
MISC | 1.1 | ||
x-value | 1.5 | ||
External Leakage | Not applicable | ||
AEC average | 129 | kWh | |
AEC cold | 129 | kWh | |
AEC warm | 129 | kWh | |
AHS Average | 28 | kWh/a | |
AHS Cold | 55 | kWh/a | |
AHS Warm | 13 | kWh/a |