Panther TPNT135 Fan Heater Panther T

Panther T Wall Mounted Fan Heaters

Powerful fan heater for technical heating

  • Compact with high output

  • Easy mounting with flexible wall bracket

  • Long service life

  • For installations not covered by the Ecodesign Regulation

PNT135 Fan Heater Panther T#334030

Protects your equipement

Panther T is an efficient fan heater for stationary use that provides fast and effective heating for your technical environments. The investment in Panther T is minor compared to potentially high damage costs caused by frost or humidity.

Compact and Robust

Panther T is a powerful and robust fan heater with a long service life. The fan heater is easy to install and requires a minimum of maintenance, which reduces costs and the risk of errors.

External Control

Panther T must be supplemented with an external control panel PP. It provides easy operation and can control multiple units simultaneously. The fan heater should be installed with an external thermostat. Thermostat controls are available as accessories.

Versatile Wall bracket

Supplied with a versatile wall bracket that makes it possible to direct the airflow where it's needed, downwards and to the side. 

Panther T is a series of efficient fan heaters designed for drying and heating installations of a more technical nature. Panther T is suitable in, for example, service areas, utility rooms and drying rooms.

Panther is mounted on the wall and comes with a wall bracket that makes it possible to direct the air flow downwards and to the side (30° left or right).

Panther T must be supplemented with a control panel PP. Up to 6 units can be controlled by one control panel. PNT135 requires one PP15N per unit. The fan heater should be installed with an external thermostat.

Tech specs

Technical Data

Article name
PNT135 Fan Heater Panther T
Article number
#334030
440V 3~
Nominal data
Color casingTraffic white
Color casing, RALRAL 9016
Enclosure classIP44
Ambient working temperature (dry conditions)-20 to 30°C
Dimensions and weights
Width450mm
Height520mm
Depth510mm
Weight24kg
Air flow
Air flow1300; 900m³/h
Sound data
Sound level31; 23dB(A)
Sound pressure (LpA)Conditions: Distance to the unit 3 metres. Directional factor: 2. Equivalent absorption area: 200 m².
Sound power (LWA)61dB(A)
Conditions sound levelMeasurements according to ISO 27327-2: 2014, Installation type E.
Motor/control supply
Control/motor supply230V
Phases, motor1~
Input power (P1), motor70W
Electric heat
Current heating13.4A
Voltage heating440V
Input power, heater10; 5kW
Phases3~
Temperature rise, maximum heat output, highest airflow31°C
Temperature rise, maximum heat output, lowest airflow45°C
Others
Heat output [kW]13.5kW

Performance