Systemair Application area (Skyline)

Data centre cooling solutions

Safe, energy-efficient cooling systems, delivering high profitability with maximum uptime

  • Small to Large-scale Data Centres

  • Server Rooms

Cooling: Mission-critical for data centres and server rooms

As global demand for online processes and data transmission skyrockets, the need for building more and more energy-efficient data centres increases.

At Systemair, we offer a range of reliable, highly energy-efficient cooling solutions that work at their best all year round with minimal impact on the environment. So you can confidently meet local, national and international energy efficiency standards without compromising the performance of your data centre.

Precise and reliable operations

Maximum energy efficiency

Easy maintenance and installation

Long-term sustainability

Why choose Systemair?

0003 Dcc Solutions Green

Focus on energy efficiency

Systemair strives to minimise environmental impact through the development of energy-efficient products, reducing resource consumption, and implementing a life-cycle approach to product design. We continuously stay at the forefront of smart manufacturing technology.

With a team of over 200 R&D engineers spread across 10 technical centres worldwide, we provide a wide range of robust and reliable products suitable for all sizes of data centres, even in the most challenging climatic conditions. Our products are developed according to the latest standards and undergo rigorous testing to ensure quality and reliability.

 

Ultimate flexibility to meet every need

Systemair’s cooling products come with multiple configuration options that allow for high customisation, so you can rest assured there is always an optimal way to cool your data centre, including:

  • Solutions for limited space

  • Lego principle for cooling in high-density spaces

  • Options for extreme climate

For projects with specific requirements that can not be met with standard products, Systemair engineers develop optimal tailor-made solutions together with our customers, taking into consideration all the particular needs.

Pre-tested to ensure performance

Accurate and stable performance of the cooling units is extremely important for data centre facilities.

In Systemair's Testing facility “365 Performance Centre” our customers can see units performing under simulated conditions.

Thanks to a wide capacity range of the testing equipment, our units can be fully tested under data centre heat load and even the most challenging ambient conditions, including:

  • Real server rack simulation up to 500kW load

  • Outdoor air test conditions from -5 °C to +45 °C

  • Controls and alarm simulation testing

The Test Centre is AMCA210 accredited for airflows from 5,000 m³/h to 100,000 m³/h. All measurement techniques used are conducted in accordance with ASHRAE I43-2015.

Discover our product range

Geniox Tera Product Family

Geniox Tera I

Indirect Free-Cooling Units
  • Cooling capacity up to 300 kW

  • Low pPUE

  • Significantly reduces or eliminates the need for mechanical cooling

Geniox Tera D

Direct Free-Cooling Units
  • Cooling capacity up to 400 kW

  • High scalability

  • Customisable configurations to meet diverse needs

Geniox Tera F

Fan Wall Units
  • Cooling capacity up to 500 kW

  • Flexible and compact design

  • Easy maintenance access

365 Performance Centre

We are by your side. From concept to completion.

Shutterstock 1515843725

Factory Acceptance Test in brand new modern testing laboratory

The right way to ensure you are making the best choice for your project.

Data Centre Server Room

Service and commissioning by our highly trained service team

The right way to ensure you are making the best choice for your project.

Customer trainings and academies

The right way to ensure you are making the best choice for your project.

SysTemp P, Close control air conditioning units ideal for data centres
SysTemp P
Close control air conditioning units ideal for data centres