Systemair solutions safeguard the indoor climate of Lego’s factory year-round amidst Mexico’s extreme temperature fluctuations
Lego Factory, Mexico
Systemair manufactured customised ventilation solutions for the factory of Lego, one of the world’s largest toy companies, in Mexico. The solutions were tailored to meet the factory’s requirement of ensuring a reliable and comfortable indoor climate that can accommodate extreme ambient temperatures and comply with strict SFP levels.
Manufactured and combined AHUs to meet high flow rates and large floor area
Systemair solutions were designed for superior humidity and temperature control and align with energy performance requirements, particularly SFP values
The local office in Mexico worked closely with the client to design, deliver and install AHUs and fire dampers in keeping with SOP requirements.
Cowi
Demek
Lego Mexico
Grupo Garza Ponce
Lego A/S is a Danish toy production company based in Billund, Denmark. It manufactures Lego-brand toys, mainly consisting of interlocking plastic bricks. In 2012, it was reported that The Lego Group had become the world's most valuable toy company, ahead of Mattel, with a value of over USD 14.6 billion.
Lego has three leading factories: Billund in Denmark, Nyíregyháza in Hungary, Kladno in the Czech Republic, Jianxing in China, and Monterrey in Mexico. These factories produce 36,000 lego pieces per minute.
Systemair manufactured and delivered ventilation solutions for the Monterrey factory in Mexico. The project consisted of two phases related to the new state-of-the-art building onsite—the project focused on the new building’s AHUs and fire dampers. The new facility measures 100,000 m2 and will be dedicated to processing cooling for the moulding throughout the production process. Several AHUs were also required as part of the retrofit efforts for a nearby, older building which features the kitchen, office, and warehouse facility.
The Monterrey factory houses 3,500 employees working on moulding, processing and packing, supplying to markets in The Americas.
The project's main challenges are related to:
meeting the customer's quality standards
delivering units with high flow rates and huge sizes
having to assemble crossflow recuperators of immense dimensions.
The AHUs needed to maintain certain humidity and temperature inside the building. The ventilation solutions had to be designed with a high volume of fresh air to reliably accommodate the extreme temperature fluctuations in Monterrey throughout the year, which can be as low as 0°C in the winter season and as high as 42°C in the summertime.
It was also critical that the AHUs effectively comply with Lego’s requirements which align with European energy performance standards. In fact, the SFP value was one of the key compliance requirements. In addition, the solutions also had to meet parameters related to the unit’s construction and technical features, such as thermal bridge (TB2), transference resistance (T2), efficiencies in the heat exchangers and materials in the components like ALMG in the coils.
A key factor was that Systemair could deliver the specs with SystemairCAD despite the project’s complexity
To meet these requirements and due to the complex nature of the venture, Systemair manufactured 27 air handling units and combined them into 16 complex air handling units. Each complete unit had a lot of components, including double heat exchange and double cooling coil and heating elements, making it a one-of-a-kind solution.
Overall, Systemair delivered the following for the first design phase of the new building:
16 Geniox air handling units and 1 DV190 (Custom-developed from initially 27 units)
1000 fire dampers
The flow rates of the equipment supplied ranged from 1,400 m3/h to 40,000 m3/h. While the new building saw the installation of the fire dampers and most of the AHUs, Systemair also installed a few of the units as part of retrofits to the older building on site.
Systemair became the supplier of choice owing to its extensive and high-quality portfolio of products, which exceeded the client’s expectations. However, the team’s personalised service and support through the local office in Mexico truly made the project a success.
Rodrigo Olea, Mexico Sales Manager, Systemair, said: “Through our sales office, we worked very closely with the client from the very beginning. We facilitated the selection to meet all specs that LEGO required, including liaising with manufacturing companies of components integrated with the AHUs and LEGO. We also provided the scheduling and logistics to ensure that the units were delivered according to LEGO’s standard operating procedure (SOPs). Once the units were on site, we provided regular site visits to make sure the units were assembled according to factory instructions and operate as intended.”
All units supplied have been operating since December 2021. The 2nd phase of the new is still underway
Phone: +52 55 13287328
Av. Insurgentes Sur 1388, int. 101, Actipan, Benito Juarez, Mexico, CP. 03230, , Mexico