OPTIMA-R-FM-080-BM

OPTIMA-R-FM Variable Air Volume Controllers

Airflow measurement device suitable for circular-shaped ventilation ducts

  • Precision readings 

  • Compact 

  • No maintenance 

  • Galvanised steel 


OPTIMA-R-FM-080-BM#277085

Continuous reading

The OPTIMA-R-FM air flow measurement device is intended for continuous reading of the airflow volume in circular-shaped ventilation ducts. 


No maintenance required

The OPTIMA-R-FM air flow measurement device requires no regular maintenance to keep operating. 


Compact size

The compact size of the OPTIMA-R-FM  air flow measurement device allows for discreet installation in a range of settings. 


The OPTIMA-R-FM is a compact airflow measurement device that provides a continuous precision reading of the airflow volume in circular-shaped ventilation ducts. The airflow volume is interpreted and transmitted by the analogue signal or by bus communication. The OPTIMA-R-FM air flow measurement device requires no regular maintenance to keep operating. 

The unit consists of a circular-shaped casing from galvanised steel with rubber gaskets on the spiro-duct connection part. Inside it is equipped with an airflow measurement probe of dynamic ΔP type. The airflow transmitter is attached and connected to the measurement probe by flexible impulse tubes to the outside of the device. This compact device is designed to provide precision measurements in a wide range of settings and is available in different sizes.


Tech specs

Technical Data

Article name
OPTIMA-R-FM-080-BM
Article number
#277085
Nominal data
Communication dataBUS
Voltage (nominal)24V
Power consumption in wire2VA
Dimensions and weights
Weight1.15kg

Performance

Dimensions

Specification

Round air flow rate measuring device for continuous measurement of the air flow rate. The air flow rate is interpreted and transmitted using an analog signal or bus communication.Housing made of galvanized steel with pipe connections on both sides with lip seals.The measurement graticule is made of aluminum.Hose-connected and wiredBELIMO or SIEMENS communication unit.HighlightsPrecise continuous measurement of air flow rateMeasurement data transmission via analog signal or bus line: Modbus or BACnetCompact dimensionsMaintenance freeTechnical specificationAvailable nominal sizes from DN 80 to DN 630 mm in 15 gradations.Airflow range from 18 to 12344 m³/hMeasuring accuracy: 5–10%Operating temperature: -20°C to +50°C - Size: 80- Equipment, Communication type: Belimo, Analog, Modbus, BACnet- Airflow direction: Supply- Vnom: 199 m³/h