Tech specs

Technical Data

Article name
SYSVRF3 CEILING 36 Q
Article number
#459352
Performances
Power input heating4kW
Cooling capacity3.6kW
Power input16W
Max. operation current0.2A
Recommended fuse15 A
General data
Air volume [m³/h]564/539/514/492/467/445/424
Refrigerant typeR410A / R32
Power supply230V/ 1~Ph /50Hz
Frequency50Hz
Phases1~
Air volume564/539/514/492/467/445/424
Operating ambient temperature range cooling+17…+32°C
Operating ambient temperature range heating+10…+28°C
Dimension liquid pipe6,35 (1/4”)
Dimension gas pipe12,7 (1/2”)
Dimension (WxHxD)1,069 x 674 x 234
Dimension packing (WxHxD)1,190 x 755 x 313
Drain pipeOD 25
Design pressure (H/L) (bar)44/26
Sound data
Sound pressure level dB(A)32/30/29/28/27/26/25
Sound power level dB(A)43/42/40/39/38/38/37
Dimensions and weights
Height674mm
Depth234mm
Width1,069mm
Weight24.7kg
Gross weight29.5kg
Nominal conditions
Indoor unit cooling27°C DB, 19°C WB
Indoor unit heating20°C DB, 15°C WB

Dimensions

SYSVRF3 CEILING #459352, Dimensions

Accessories

SYSVRF3 KNX-GW
#456130 · SYSVRF3 KNX Gateway 1IDU D1D2
SYSVRF3 RM12
#456126 · VRF3 IR-Controller, FollowMe, ECO
SYSVRF3 WGC86T
#456127 · VRF3 Single/Group control 16IDU,W-Timer
SYSVRF3 WGC86S
#456128 · VRF3 Single/Group control 16IDU
SYSVRF3 M1/M2-Repeater
#466114 · M1/M2 Signal Repeater, <10IDU, <200m
SYSVRF JOINT IN 07 2P
#316272 · 2pipe VRF indoor unit joint
SYSVRF JOINT IN 06 2P
#314154 · 2pipe VRF indoor unit joint
SYSVRF JOINT IN 04 2P
#314152 · 2pipe VRF indoor unit joint
SYSVRF JOINT IN 03 2P
#314151 · 2pipe VRF indoor unit joint
SYSVRF JOINT IN 02 2P
#314150 · 2pipe VRF indoor unit joint
SYSVRF JOINT IN 01 2P
#314149 · 2pipe VRF indoor unit joint