Compact and powerful fan for your professional environment
High-Performance
Compact deisign
Simple installation in any position
Maintenance-free and reliable
The CE/CT series of centrifugal fans are designed for indoor use with stable power performance for extract or supply air.
The CE/CT fan has a compact form factor and can be installed in any required position. This supports various applications (commercial, industrial and residential).
Compliant with today’s and tomorrow’s European Union rules and requirements for energy labelling and ecodesign for Energy-related Products (ErP).
CE/CT fan casing made of galvanised sheet steel, corrosion class C3. Shape of the casing designed to obtain high efficiency.
CE fans are equipped with terminal box IP44 to simplify wiring process on site. CT fans are equipped with cable to connect to the external terminal box (separate accessory).
Single inlet radial impellers with forward curved blades. Made of lightweight PP for sizes 125/160 and galvanised sheet steel for bigger sizes. All impellers dynamically balanced and paired with corresponding external rotor motors.
CE/CT fans are equipped with AC external rotor motor, insulation class B. All motors are supported by long-life ball bearings.
CE Fans have integrated thermal protection with manual (electrical) reset.
CT Fans have integrated thermal contact with external leads for connection to a motor protection device (separate accessory).
All fans are controlled by 5-step or stepless speed regulator provided as accessory. Speed regulation can be combined with timer, thermostat, hygrostat, etc. by using wide range of electrical accessories.
Mounting of the CE/CT fans possible indoor in any mounting position.
CE models used standard inlet and outlet flanges to maximise adaptability with corresponding FK fast clamps.
230V 1~ 50Hz | |||
---|---|---|---|
Nominal data | |||
Voltage (nominal) | 230 | V | |
Frequency | 50 | Hz | |
Phases | 1~ | ||
Input power | 125 | W | |
Input power kW | 0.125 | kW | |
Input current | 0.54 | A | |
Impeller speed | 1,807 | rpm | |
Air flow | max 436 | m³/h | |
Capacitance of capacitor | 4 | µF | |
Temperature of transported air | max 65 | °C | |
Max temperature of transported air, when speed controlled | 65 | °C | |
Sound data | |||
Sound pressure level at 3m (20m² Sabin) | 42 | dB(A) | |
Protection/Classification | |||
Enclosure class, motor | IP44 | ||
Insulation class | B | ||
Data according to ErP | |||
Energy class, Basic unit | F | ||
Energy class, Local demand | C | ||
ErP ready | ErP 2016; ErP 2018 | ||
Dimensions and weights | |||
Duct dimension; Circular, inlet | 160 | mm | |
Duct dimension; Circular, outlet | 160 | mm | |
Weight | 3.1 | kg | |
Others | |||
Duct connection type | Circular | ||
Motor type | AC |
230V 1~ 50Hz | ||||
---|---|---|---|---|
Basic unit | ||||
ErP compliance | 2016 | |||
SEC Average | -9.1 | kWh/(m².a) | ||
SEC Cold | -25.5 | kWh/(m².a) | ||
SEC Warm | 0.3 | kWh/(m².a) | ||
SEC Class | F | |||
Unit category | RVU | |||
Unit type | UVU | |||
Drive | External MSD or VSD | |||
Heat recovery type | None | |||
Temperature ratio (UVU) | Not applicable | |||
qv max | 385 | m³/h | ||
P max | 114 | W | ||
Sound power (LWA) | 42 | dB(A) | ||
qv ref | 0.075 | m³/s | ||
Ps ref | 50 | Pa | ||
SPI | 0.258 | W/(m³/h) | ||
CTRL | 1 | |||
MISC | 1.1 | |||
x-value | 1.5 | |||
External Leakage | 5 | % | ||
AEC average | 322.6 | kWh | ||
AHS Cold | 322.6 | kWh | ||
AEC warm | 322.6 | kWh | ||
AHS Average | 1,715.2 | kWh/a | ||
AHS Warm | 775.6 | kWh/a | ||
Units with local demand control | ||||
ErP compliance | 2018 | |||
SEC Average | -24.1 | kWh/(m².a) | ||
SEC Cold | -51.1 | kWh/(m².a) | ||
SEC Warm | -8.6 | kWh/(m².a) | ||
SEC Class | C | |||
Unit category | RVU | |||
Unit type | UVU | |||
Drive | External MSD or VSD | |||
Heat recovery type | None | |||
Temperature ratio (UVU) | Not applicable | |||
qv max | 387 | m³/h | ||
P max | 114 | W | ||
Sound power (LWA) | 42 | dB(A) | ||
qv ref | 0.0752 | m³/s | ||
Ps ref | 50 | Pa | ||
SPI | 0.258 | W/(m³/h) | ||
CTRL | 0.65 | |||
MISC | 1.1 | |||
x-value | 1.5 | |||
External Leakage | 5 | % | ||
AEC average | 169.1 | kWh | ||
AEC cold | 169.1 | kWh | ||
AEC warm | 169.1 | kWh | ||
AHS Average | 2,830 | kWh/a | ||
AHS Cold | 5,536.2 | kWh/a | ||
AHS Warm | 1,279.7 | kWh/a |