Basic fan heater for total heating of larger premises
Efficient Operation
Wall Mounted
Industrial Design
For Water Connection
Fan heater SWS has a compact and functional design well suitable for places where fan heaters are traditionally used, such as industrial premises.
The fan heater gives high output and provides fast and efficient heat at low cost. Easy installation and maintenance minimizes cost.
The SWS fan heater is mounted on the wall. By turning the fan heater, pipe connections are possible on both sides.
The unit has a casing of grey alu-zinc coated steel panels and louvres in anodised aluminium. This makes the entire unit highly resistant to corrosion.
Fan heater SWS is intended for water-heating and is suitable for places where fan heaters are traditionally used, such as industrial premises, workshops and storage rooms.
SWS is permanently mounted to a wall or the ceiling with brackets that can be ordered separately. The fan motor is connected to a detached terminal box mounted on the wall next to the unit (230V~) or a terminal box which is positioned on the motor itself (400V3~). By turning the fan heater, pipe connections are possible on both sides.
Wide range of controls and accessories.
Water heated units must be supplemented with a valve system. The valve system controls the water flow and activates maximum heat only when needed.
Default | |||
---|---|---|---|
Nominal data | |||
Color casing | Grey alu-zink | ||
Color, outlet grilles | Aluminum / Aluminum | ||
Enclosure class | IP44 | ||
Ambient working temperature (dry conditions) | -20 to 40 | °C | |
Dimensions and weights | |||
Width | 520 | mm | |
Height | 470 | mm | |
Depth | 260 | mm | |
Weight | 14 | kg | |
Air flow | |||
Air flow | 1260; 1150; 1010; 780; 520 | m³/h | |
Sound data | |||
Sound level | 50; 48; 45; 36; 27 | dB(A) | |
Sound pressure (LpA) | Conditions: Distance to the unit 5 metres. Directional factor: 2. Equivalent absorption area: 200 m². | ||
Sound power (LWA) | 65 | dB(A) | |
Conditions sound level | Measurements according to ISO 27327-2: 2014, Installation type E. | ||
Motor/control supply | |||
Control/motor supply | 230 | V | |
Control/motor current | 0.33 | A | |
Input power (P1), motor | 75 | W | |
Water data | |||
Water heating full output 80/60 °C, air +15 °C | 12 | kW | |
Water heating full output 60/40 °C, air +15 °C | 7.1 | kW | |
Pressure drop water 80/60 °C, air +15 °C | 6.5 | kPa | |
Pressure drop water 60/40 °C, air +15 °C | 2.8 | kPa | |
Water temperature | max 150 | °C | |
Maximum working pressure | 1 | MPa | |
Water volume inside coil | 1.3 | L | |
Dimension water connections | 22 mm | ||
Nominal size | DN22 | ||
Others | |||
Heat output [kW] | 12 | kW |